★ ★
 
ホーム    マイ・リポジトリ        English    新潟県大学図書館協議会    ご意見  

新潟県地域共同リポジトリ >
日本歯科大学新潟生命歯学部 >
10 学術雑誌論文 = Journal Article >
10 査読済論文 = Postprint >

 

登録ファイル

ファイル 記述 サイズフォーマット
ishida.pdf2364KbAdobe PDF
タイトル :Shear bond strength of rebonded brackets after removal of adhesives with Er,Cr:YSGG laser
著者 :Ishida, Katsuyuki
Endo, Toshiya
Shinkai, Koichi
Katoh, Yoshiroh
公開者・出版者 :Springer
刊行年月 :2011-7
掲載誌名 :Odontology : Official journal of the Society of the Nippon Dental University
巻 :99
号 :2
開始ページ :129
終了ページ :134
ISSN :1618-1247
抄録 :This study was conducted to examine the bond strength of rebonded orthodontic brackets after adhesive residuals on the surface of the bracket bases were removed by Er,Cr:YSGG lasers. Seventy-six brackets bonded to premolars with a self-etching primer adhesive system were equally divided into four groups after the first debonding with the bracket bases (Group 1) untreated, and treated by (Group 2) Er,Cr:YSGG laser, (Group 3) sandblaster, and (Group 4) Er,Cr:YSGG laser/sandblaster. The treated brackets were rebonded to the new premolars in the same manner as the first-stage experiment. The shear bond strengths were measured, with the bonding/debonding procedures repeated once after the first debonding, and the bracket/adhesive failure modes were evaluated after each debonding. The treated bracket base surfaces were observed under a scanning electron microscopy (SEM). The mean rebond strengths were significantly lower in group 1 than in other groups, and that there were no significant differences between the other groups. The mean initial bond strength was significantly higher than the mean rebond strength in group 1 but there was no significant difference between the two in the other three groups. Failures at the bracket-adhesive interface occurred frequently at second debonding in group 1. Under the SEM, residual adhesive was removed from the bracket bases by Er,Cr:YSGG laser, while adhesive remnant was seen underneath the meshwork of the bracket bases and microroughness appeared on the meshwork after sandblasting. Er,Cr:YSGG laser certainly could serve the purpose of promoting the use of recycled orthodontic brackets.
キーワード :Er,Cr:YSGG Laser
Recycled brackets
Shear bond strength
Adhesive remnant index
資料種別 :Journal Article
言語 :eng
URI :http://hdl.handle.net/10623/31740
出現コレクション:10 査読済論文 = Postprint

引用の際は次の識別子を使用してください http://hdl.handle.net/10623/31740

・学術リポジトリに登録されている研究成果の著作権は,著者,出版社(学協会)などが有します。

・学術雑誌に掲載された論文等は,発行された誌面とはレイアウトの相違や文言の違いなどがあり得ます。

・表示・ダウンロードした研究成果は,著作権法に規定されている私的使用,引用等の範囲内で利用してください。